• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Indexing and Abstracting
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Egyptian Journal of Botany
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 65 (2025)
Issue Issue 3
Issue Issue 2
Issue Issue 1
Volume Volume 64 (2024)
Volume Volume 63 (2023)
Volume Volume 62 (2022)
Volume Volume 61 (2021)
Volume Volume 60 (2020)
Volume Volume 59 (2019)
Volume Volume 58 (2018)
Volume Volume 57 (2017)
Volume Volume 56 (2016)
Volume Volume 55 (2015)
Volume Volume 54 (2014)
El-Batrawy, O., Hasballah, A. (2025). Monitoring of toxinogenic producing fungi in air conditioning system dust at some clinics.. Egyptian Journal of Botany, 65(3), 645-659. doi: 10.21608/ejbo.2025.347785.3137
Omnya A. El-Batrawy; Amany F. Hasballah. "Monitoring of toxinogenic producing fungi in air conditioning system dust at some clinics.". Egyptian Journal of Botany, 65, 3, 2025, 645-659. doi: 10.21608/ejbo.2025.347785.3137
El-Batrawy, O., Hasballah, A. (2025). 'Monitoring of toxinogenic producing fungi in air conditioning system dust at some clinics.', Egyptian Journal of Botany, 65(3), pp. 645-659. doi: 10.21608/ejbo.2025.347785.3137
El-Batrawy, O., Hasballah, A. Monitoring of toxinogenic producing fungi in air conditioning system dust at some clinics.. Egyptian Journal of Botany, 2025; 65(3): 645-659. doi: 10.21608/ejbo.2025.347785.3137

Monitoring of toxinogenic producing fungi in air conditioning system dust at some clinics.

Article 26, Volume 65, Issue 3, July 2025, Page 645-659  XML PDF (1.76 MB)
Document Type: Regular Issue (Review)
DOI: 10.21608/ejbo.2025.347785.3137
View on SCiNiTO View on SCiNiTO
Authors
Omnya A. El-Batrawy1; Amany F. Hasballah email 2
1Environmental sciences Department, Faculty of Science, Damietta University
2environmental sciences,faculty of science,Damietta university
Abstract
Eighty four samples out of 1260 isolates from; filter's dust, wing's dust, indoor air without air condition and indoor air with air condition (14 for each) were collected every month through four months in this study from 14 clinics in Damietta Governorate, North East of Egypt. Aeromycobiota were isolated by open plate and filtration techniques, while filter and wing dusts were isolated using dilution plate technique on Czapek’s Yeast Extract Agar, Potato Dextrose Agar, and Dichloran-Glycerol-18 Agar. Eight taxa belonging to five genera were recovered in dust during this survey: Aspergillus, Mucur, Fusarium, Penicillium and Alternaria. The dust accumulated fungi number of wing and filter dust (DAF) ranged from 120 to 1240 and 60 to 480 CFU/cm2, respectively. Indoor air of the clinics before and after turning on AC collected by open plate technique is contaminated with twelve fungal species from six genera. While that was collected by filtration technique is contaminated with nine fungal species from six genera. Results revealed that some isolated fungi had ability to produce Aflatoxins as A. flavus & A. parasiticus and Ochratoxin A as A. niger & A. ocraceus
Keywords
Indoor air quality; mycotoxins; medical facilities; aeromycobiota; air conditioning system
Statistics
Article View: 67
PDF Download: 27
Home | Glossary | News | Aims and Scope | Sitemap
Top Top

Journal Management System. Designed by NotionWave.